Off grid inverters Max5000
Last Updated
15 Jan 2019
Country Origin
Taiwan
Minimum Order
1 unit
Category
Solar InverterSubcategory
OFF GRIDSpecification of Off grid inverters Max5000
Off grid inverters Max5000
PASCAL SOLAR HYBRID UPS 5000VA
This is a pure sine wave stand-alone inverter/charger system combining the
function of inverter, solar charger and AC charger, and provides a long
run-time uninterruptible power supply. Its comprehensive LCD display
provides system status, and user-friendly panel eases parameters settings.
Key Feature:
- High-frequency switching technology for compact size and light weight
- Pure sine wave output for wide range of applications and harsh environment
- Build-in solar charger controller with MPPT technology to optimize the power utilization
- High efficient DC-to-AC conversion minimizing energy loss
- Standby Charging Mode enables battery charging even when the unit is switched off
- Intelligent cooling fan control
- Input/output isolated design for the maximum operation safety
- LCD displays comprehensive operation status
- Configurable AC input voltage range and priority for AC input or PV input
- Supports Home Appliances / Office Equipment/ Lighting Equipment/ Motor-based Equipment (such as Fan, Air-Conditioner, Washing Machines)
- Thorough protections: Input low voltage / Overload / Short circuit / Low battery alarm / Input over voltage / Over temperature
- Supports both rack and wall-mounting set-up for flexible installation
SPECIFICATION:
MODEL | MAX 5000 |
---|---|
CAPACITY | 4.2KW/5000VA |
INPUT | |
Input Voltage Waveform | Pure sine wave (utility or generator) |
Nominal Input Voltage | 230Vac |
Input voltage range | 175Vac-280Vac(Normal) ; 125Vac-280Vac(Generator/Wide) |
Max AC Input Voltage | 300Vac RMS |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
OUTPUT | |
Wave from | Pure sine wave (Inverter mode) |
Voltage Regulation (Inverter Mode) | ±10% RMS |
Output Frequency | 50Hz / 60Hz ± 1Hz |
Nominal Efficiency | 90% (@Inverter mode with normal DC Input; >60% R load); 95% (@Line mode with Rated R load, battery full charged) |
Capable of starting electric motor | 2.5HP |
Power Factor | 0.84 |
Over-Load Protection | Tripped off after 5s@≥150% load Tripped off after 10s@110%~150% load |
Transfer Time (AC to DC) | Normal range : 10ms (typical) 15ms (max) Generator/wide range: 20ms (typical) 40ms (max) |
BATTERY | |
Battery Voltage | 48.0Vdc± 1.2Vdc |
Battery low alarm voltage | 42.0Vdc± 1.2Vdc |
Battery low shut-down voltage | 40.0Vdc ± 1.2Vdc |
AC CHARGER | |
Charger Current | 25A @180V~280V; 20A @125V~180V |
Boost charger voltage (bat. Type) | 56.8Vdc |
Floating charger voltage (bat. Type) | 54.8Vdc |
Over charger Voltage | 60.0Vdc |
SOLAR CHARGER MODULE | |
Max Charger current | 60A |
Charger Power | 2400W |
System DC Voltage | 48.0Vdc |
Operating Voltage Range | 60~150Vdc |
PV Optimal Work Voltage Range | 90~144Vdc |
Max. PV Array Open Circuit Voltage | 150Vdc |
MAX. PV Input Current | 30A |
AUDIBLE ALARM | |
Low Battery at Inverter Mode | Beeps 1 time every 2s |
Overload | 110%~150%load: beep 10 times every 0.5s; >150% load: beep 5 times every 0.5s then fault. |
Fault | Beeps continuously |
PHYSICAL | |
Dimension(D*W*H)mm | 428.5mm*350.4mm*119.1mm |
Net weight | 10.4kg |